Abstract
Breast DCE-MRI AI is increasingly being explored for breast-level classification of no-lesion, benign, and malignant findings, beyond conventional lesion-centered diagnosis. Within this broader diagnostic scope, however, patient-specific background variability remains a major source of imaging confounding across classification tasks. Existing approaches predominantly focus on unilateral or lesion-centric analysis, whereas bilateral methods offer limited explicit modeling of spatially adaptive cross-breast correspondence. We propose PRISM-Net, a registration-free bilateral framework that leverages contralateral breast features as patient-specific references for background-aware representation learning. PRISM-Net integrates bilateral feature matching and asymmetry-aware attention to establish adaptive inter-breast correspondence and enhance representations of discriminative asymmetric patterns. On ODELIA, Macro AUC, Micro AUC, and quadratic weighted kappa were 84.11 ± 2.33, 90.64 ± 1.61, and 60.94 ± 5.64 on the in-distribution test set, and 68.51 ± 4.54, 80.74 ± 2.68, and 43.45 ± 7.10 on the held-out institution, respectively, outperforming the evaluated baseline methods across the primary evaluation metrics. PRISM-Net further demonstrated performance on independent institutional and background-complexity evaluations. Ablation experiments revealed that both bilateral relation modeling and asymmetry-aware reweighting contributed to improved classification performance. These findings highlight patient-specific bilateral reference modeling as a clinically grounded strategy for DCE-MRI interpretation, improving asymmetric pattern discrimination through explicit modeling of background complexity.